Executive Summary
Environix has been authorized to perform a lead-based paint survey at the property.
Environix was hired to conduct a limited scope lead based paint investigation during a pre-sale inspection process for an agreed upon scope of No more than 7 samples per room throughout the property.
The Survey of the painted components for the home was performed using an INNOV-X ALPHA Series INNOV-X Alpha SeriesX-ray fluorescence (XRF) lead paint Analyzer (Instrument serial #2573 ). The data collected is in the section titled XRF Results.
Definition of Key Terms:
Wall “A” or “1” in each room is the wall where the front entrance door opening is located (or
Aligned with front parking). Going clockwise and facing Wall “A” or “1”, Wall “B” or “2” will
always be to your right, Wall “C” or “3” directly to the rear and Wall “D” or “4” to the
left. Doors, windows and closets are designated as left, center or right depending on their
location on the wall. Doors, windows, and closets are designated as left, center or right
depending on their location on the wall.
In addition, an inspection of an agreed upon scope of painted surfaces throughout the
entire property was performed in conjunction with the XRF testing to determine which
lead-based painted surfaces/components are deteriorated (above the de minimal level).
Units of Measure:
Lead based paint is classified as having a lead content of above 1.0 mg/cm².
mg = Milligram (1/1000th of a gram)
ppm = Parts per Million
cm² = Square Centimeter
List of Lead-Positive Testing Combinations:
| Reading | Pass Fail Standard | Room | Side | Component | Substrate | Pb | Pb +/- |
| 64 | Positive | Outside | B | Wall Siding | Wood | 1 | 0.07 |
| 66 | Positive | Outside | B | Wall Siding | Wood | 1 | 0.04 |
| 70 | Positive | Outside | C | Door | Wood | 1 | 0.07 |
Scope of Inspection
Building Background
This property was built in 1957.
Written permission was obtained to access the property .
Preface
Environix has been contracted to perform lead-based paint testing of the above referenced single family home to determine the possible presence, condition, location and amount of lead paint.
Inspection Company
The inspection was performed by Tim Klassen who is employed by Environix.
License No. 6330 Expiration Date: 05/05/2014
Environix offices are located at: 20728 56th Ave W in Lynnwood, Washington (98036).
State lead license number: 4075 Exp: 06/02/2014
The company’s telephone number is 800-351-9563.
Summary
Lead Paint Discovered
It was determined that lead based paint was discovered at the residence at or above lead based paint levels of 1.0 mg/cm².
Lead based paint is classified as having a lead content at or above 1.0 mg/cm².
Special remediation and/or paint stabilization is required when disturbing building materials on this site in these location(s):
| Reading | Pass Fail Standard | Room | Side | Component | Substrate | Pb | Pb +/- |
| 64 | Positive | Outside | B | Wall Siding | Wood | 1 | 0.07 |
| 66 | Positive | Outside | B | Wall Siding | Wood | 1 | 0.04 |
| 70 | Positive | Outside | C | Door | Wood | 1 | 0.07 |




